MkW AM080MXWANR/EU AM100MXWANR/EU AM120MXWANR/EU Power Supply Φ, #, V, Hz 3Φ, 4, 380–415 V, 50/60 Hz 3Φ, 4, 380–415 V, 50/60 Hz 3Φ, 4, 380–415 V, 50/60 Hz Performance HP HP 8 10 12 Capacity (Nominal) Cooling kW 22.4 28.0 33.6 Heating kW 25.2 31.5 37.8 Maximum number of connectable indoor units ea 14 18 22 Total capacity of the connected indoor units Min. kW 11.2 14.0 16.8 Max. kW 29.1 36.4 43.7 Power Power Input (Nominal) Cooling kW 3.67 4.87 6.00 Heating kW 3.97 5.04 6.25 Current Input (Nominal) Cooling A 5.9 8.1 9.6 Heating A 6.4 8.4 10.0 Current Minimum SSC value MVA 3.9 3.9 4.8 MCA A 16.1 16.1 20.0 MFA A 20 20 25 COP1 Nominal Cooling W/W 6.10 5.75 5,60 Nominal Heating W/W 6.35 6.25 6.05 Compressor Type - Inverter Scroll Inverter Scroll Inverter Scroll Output kW × n 4.96 x 1 4.96 x 1 6.13 x 1 Oil Type - PVE PVE PVE Initial Charge cc 3,900 3,900 3,900 Condenser Type - Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger Pipe Size ø, inch PT 1 1/4 PT 1 1/4 PT 1 1/4 Pressure Drop kPa 22 30 43 Water Flow Rate l/min 80 96 114 Max. Pressure MPa 1.96 1.96 1.96 Liquid Pipe ø, mm 9.52 9.52 12.70 ø, inch 3/8 3/8 1/2 Gas Pipe ø, mm 19.05 22.22 28.58 ø, inch 3/4 7/8 1 1/8 Piping Connections Discharge Gas Pipe ø, mm 15.88 19.05 19.05 ø, inch 5/8 3/4 3/4 Piping length Outdoor-Indoor Max. m 170 (190) 170 (190) 170 (190) After branch Max. m 90 90 90 Total piping length System Actual m 500 500 500 Level difference Outdoor-Indoor Outdoor unit in highest position m 50 50 50 Indoor unit in highest position m 40 40 40 Indoor-Indoor Max. m 50 50 50 Wiring Connections Communication Minimum mm² 0.75 0.75 0.75 Remark - F1, F2 F1, F2 F1, F2 Refrigerant Type - R410A (Fluorinated greenhouse gas, GWP=2,088) Factory Charging kg 5.5 5.8 6.0 tCO₂e 11.48 12.11 12.53 Sound Sound Pressure2 Cooling dB(A) 48 48 50 Heating dB(A) 51 51 52 Sound Power dB(A) 70 70 70 External Dimensions Net Weight kg 160.0 160.0 160.0 Net Dimensions (W x H x D) mm 770 x 1,000 x 545 770 x 1,000 x 545 770 x 1,000 x 545 Operating Temperature Range Cooling °C 10.0~45.0 10.0~45.0 10.0~45.0 Heating °C 10.0~45.0 10.0~45.0 10.0~45.0 • Water Cooled, Variable Refrigerant Flow Heat Pump/ Heat Recovery Unit R410A. • Suitable for indoor and outdoor installation. • Each unit houses one (8~12 HP) or two (20~30 HP) Inverter Scroll compressors with Flash Injection technology. Specifications DVM S Water 104