Model AM022DNMFKG/EU AM028DNMFKG/EU AM036DNMFKG/EU AM045DNMFKG/EU Power Supply Ф, #, V, Hz 1Ф, 2, 220~240 V, 50/60 Hz 1Ф, 2, 220~240 V, 50/60 Hz 1Ф, 2, 220~240 V, 50/60 Hz 1Ф, 2, 220~240 V, 50/60 Hz Performance Capacity (Nominal) Cooling kW 2.2 2.8 3.6 4.5 Heating kW 2.5 3.2 4.0 5.0 Power Power Input (Nominal) Cooling W 25 30 40 50 Heating W 25 30 40 50 Current Input (Nominal) Cooling A 0.19 0.22 0.29 0.37 Heating A 0.19 0.22 0.29 0.37 Current Input (Nominal) MCA A 0.78 0.91 1.04 1.22 MFA/MOP A 15 15 15 15 Fan Type - Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Number of Fans ea 3 3 3 3 Airflow Rate H/M/L (UL) m³/min 10/9.5/9 12.5/11/10.5 15/13/12 18.5 / 16 / 13.5 l/s 167/158/150 208/183/175 250/217/200 308 / 267 / 225 External Pressure Min/Std/Max mmAq 0/3/15 0/3/15 0/3/15 0 / 3 / 15 Pa 0.00 / 29.42 / 147.1 0.00 / 29.42 / 147.1 0.00 / 29.42 / 147.1 0.00 / 29.42 / 147.10 Fan Motor Model - BLDC BLDC BLDC BLDC Output x n W 153 153 153 153 Piping Connections Liquid Pipe Ø, mm 6.35 6.35 6.35 6.35 Ø, inch 1/4 1/4 1/4 1/4 Gas Pipe Ø, mm 12.70 12.70 12.70 12.70 Ø, inch 1/2 1/2 1/2 1/2 Drain Pipe Ø, mm VP25 (OD 32, ID 25) VP25 (OD 32, ID 25) VP25 (OD 32, ID 25) VP25 (OD 32, ID 25) Wiring Connections Connection with Indoor Minimum mm² 0.75 0.75 0.75 0.75 Remark - F1, F2 F1, F2 F1, F2 F1, F2 Refrigerant Type - R32(Fluorinated greenhouse gas, GWP=675) Control Method - EEV Included EEV Included EEV Included EEV Included Sound Sound Pressure¹ (H/M/L) dB(A) 33/31/29 33/31/29 34/31/28 34/31/28 Sound Power Cooling (Nominal) dB(A) 55 56 57 57 Dimensions Net Weight kg 34.2 34.2 34.2 34.2 Net Dimensions (W × H × D) mm 1200 x 250 x 700 1200 x 250 x 700 1200 x 250 x 700 1200 x 250 x 700 Additional Accessories Drain Pump Model INCLUDED INCLUDED INCLUDED INCLUDED Max. Lifting Height mm/ Liter/H 750/24 750/24 750/24 750/24 • Two-position field adjustable air return, on the bottom or at the rear of the unit. • Equipped with one Sirocco fan direct driven by a single motor. • Auto Restart function. • Automatic ESP setting. • Built-in condensation drain pump. • Built-in R32 refrigerant leak detect sensor. • Wi-Fi Control with SmartThings via SmartPhone. • Built-in Single Wi-Fi kit (MIM-H14EN) Specifications Universal Sensible MSP Duct (drain pump included) * Universal indoor units, universal controller and universal accessories can be installed both with DVM R410A and DVM R32 Outdoor units. 1 Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ depending on operation conditions. 118